Beam CalculatorLoads, sections & elastic response

Beam calculators / Optical & lighting beams

Trace the load. Understand the beam.

Gaussian Beam Peak Intensity Calculator

Calculate ideal Gaussian on-axis power density with an explicit radius convention.

Your light beam, explained visually

Optical model

Your beam & loading inputs

W
mm

Starting values are editable examples. Confirm actual supports, loads, section and material properties. Dimension switching converts geometry only; loads and properties keep their printed units.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

I0=2Pπw2

I₀ is on-axis irradiance; P is total optical power and w is the 1/e² intensity radius.

Calculate ideal Gaussian on-axis power density with an explicit radius convention.
  1. Confirm support constraints, loading plane, section and units.
  2. Enter actual geometry, loads and justified material properties.
  3. Submit the form, then interpret the result with the assumptions and limits below.
Ideal spatial profile only, no laser protective eyewear, exposure limit, damage threshold or pulse temporal model.

Gaussian Beam Peak Intensity: model and interpretation

Calculate ideal Gaussian on-axis power density with an explicit radius convention. Ideal spatial profile only, no laser protective eyewear, exposure limit, damage threshold or pulse temporal model.
For an ideal Gaussian laser beam, w is the radius at 1/e² irradiance and divergence is a half-angle unless explicitly doubled. A lighting beam angle is instead a full angular width tied to a stated photometric convention. Do not interchange radius with diameter or half-angle with full-angle.
The formula is evaluated under its stated ideal spatial model. Geometric spot size is not a uniform illuminance guarantee, measured hot-spot map, laser safety assessment or a model of a structural member.

Check the numbers

Gaussian Beam Peak Intensity Calculator: calculated examples

These scenarios are computed with the same method as the form. They are not product recommendations, code design values or complete standards tables.

Worked example with stated inputs

Total beam power = 1 W; 1/e² beam radius = 0.5 mm.

OutputComputed result
Ideal Gaussian on-axis irradiance254.647909 W/cm² peak

How the stated input changes the result

ScenarioChanged input / basisResult
0.25 mm1/e² beam radius1,018.591636 W/cm² peak
0.375 mm1/e² beam radius452.707394 W/cm² peak
0.5 mm1/e² beam radius254.647909 W/cm² peak
0.625 mm1/e² beam radius162.974662 W/cm² peak
0.75 mm1/e² beam radius113.176848 W/cm² peak
1 mm1/e² beam radius63.661977 W/cm² peak

Unchanged inputs use: Total beam power = 1 W; 1/e² beam radius = 0.5 mm. Results retain the model limitations described above.

Common questions

What limitation matters for this calculation?

Ideal spatial profile only, no laser protective eyewear, exposure limit, damage threshold or pulse temporal model.

How do I use this gaussian beam peak intensity calculator?

Calculate ideal Gaussian on-axis power density with an explicit radius convention.
I0=2Pπw2

I₀ is on-axis irradiance; P is total optical power and w is the 1/e² intensity radius.

What do the starting values represent?

They are editable numerical examples. Measure actual dimensions and use material properties, support details and loads appropriate to the real member. They are not prescribed design values or a stock-size recommendation.

Does this calculate a structural beam?

No. This page concerns the stated optical or lighting beam geometry. It does not analyze a load-bearing member or determine laser protective equipment.

Which unit system does the calculator use?

Dimension switching converts the labelled length inputs. Forces, line loads, elastic modulus and other properties retain the units printed beside them. Results include common metric and imperial equivalents where meaningful.

Can I export the calculation to Excel?

After calculation, Export CSV saves numerical results and submitted inputs. This is a text table, not a native Excel formula workbook, proprietary analysis file or signed engineering report.

Where do the formulas come from?

Published references appear below with full plain-text addresses. Formulas, assumptions, worked examples and comparison tables are stored directly in the pages; no external property lookup is required.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.

  • Edmund Optics, Propagation of a Gaussian Beam Through a Thin Lens, equations 1–5 and 25–26https://www.edmundoptics.ca/knowledge-center/application-notes/lasers/gaussian-beam-propagation/
  • NIST Guide to the SI: conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors