Beam CalculatorLoads, sections & elastic response

Beam calculators / Material & section models

Trace the load. Understand the beam.

Steel Beam Deflection Calculator

Entered steel E=200 GPa is an illustrative room-temperature value, not an allowable stress. Calculate support reactions, shear force, bending moment, slope and elastic deflection for the stated simply supported beam.

Your beam, explained visually

Pin A · Roller B

Your beam & loading inputs

m
GPa
mm
mm
mm
mm
kN/m

Starting values are editable examples. Confirm actual supports, loads, section and material properties. Dimension switching converts geometry only; loads and properties keep their printed units.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

EId4vdx4=q(x)
dMdx=V
dVdx=q(x)

Hermite beam stiffness uses consistent distributed loads. Exact element load integration recovers the response; q(x) is positive upward.

Entered steel E=200 GPa is an illustrative room-temperature value, not an allowable stress. Calculate support reactions, shear force, bending moment, slope and elastic deflection for the stated simply supported beam.
  1. Confirm support constraints, loading plane, section and units.
  2. Enter actual geometry, loads and justified material properties.
  3. Submit the form, then interpret the result with the assumptions and limits below.
Straight prismatic Euler–Bernoulli beam; linear elastic material, constant EI, small displacement and ideal supports. No shear deformation, lateral-torsional buckling, connection design, material failure, code factors or certified safe load. Entered steel E=200 GPa is an illustrative room-temperature value, not an allowable stress.

Steel Beam Deflection: model and interpretation

Entered steel E=200 GPa is an illustrative room-temperature value, not an allowable stress. Calculate support reactions, shear force, bending moment, slope and elastic deflection for the stated simply supported beam. Straight prismatic Euler–Bernoulli beam; linear elastic material, constant EI, small displacement and ideal supports. No shear deformation, lateral-torsional buckling, connection design, material failure, code factors or certified safe load. Entered steel E=200 GPa is an illustrative room-temperature value, not an allowable stress.
The x coordinate runs from left to right. Deflection and vertical reaction are positive upward; rotation and external reaction moment are positive counterclockwise; sagging internal moment is positive. Downward load inputs are converted to negative distributed q in the equilibrium equations. The member has constant EI across its modeled length.
The worked example prints the complete input basis. Each comparison row changes the labelled quantity while retaining the other example inputs. A numerical elastic response should be distinguished from an allowable design value or a manufacturer span table.

Check the numbers

Steel Beam Deflection Calculator: calculated examples

These scenarios are computed with the same method as the form. They are not product recommendations, code design values or complete standards tables.

Worked example with stated inputs

Dimension units = Metric dimensions; Beam length / first span = 6 m; Entered elastic modulus = 200 GPa; Overall flange / section width = 150 mm; Overall section depth = 300 mm; Web thickness = 8 mm; Flange thickness = 12 mm; Downward uniform load = 5 kN/m.

OutputComputed result
Maximum absolute elastic deflection4.755708 mm
Signed extreme deflection-4.755708 mm upward
Deflection extreme location3 m from left
Maximum absolute deflection0.187233 in
Signed extreme moment22.5 kN·m sagging
Signed extreme shear15 kN
Signed extreme rotation-0.002536 rad
Extreme-fibre bending magnitude38.045666 MPa
Section Ix8,870.9184 cm⁴
Support at x=0 m vertical15 kN upward
Support at x=6 m vertical15 kN upward

How the stated input changes the result

ScenarioChanged input / basisResult
3 mBeam length / first span0.297232 mm
4.5 mBeam length / first span1.504736 mm
6 mBeam length / first span4.755708 mm
7.5 mBeam length / first span11.610616 mm
9 mBeam length / first span24.075773 mm
12 mBeam length / first span76.091332 mm

Unchanged inputs use: Dimension units = Metric dimensions; Beam length / first span = 6 m; Entered elastic modulus = 200 GPa; Overall flange / section width = 150 mm; Overall section depth = 300 mm; Web thickness = 8 mm; Flange thickness = 12 mm; Downward uniform load = 5 kN/m. Results retain the model limitations described above.

Common questions

Are the plotted lines also used to locate the maximum?

The plotted points illustrate the response. Extrema are evaluated separately at element boundaries and roots of the exact equilibrium/rotation polynomials, including the distributed-load displacement term.

Does this include shear deformation or lateral-torsional buckling?

No. This is a small-deflection Euler–Bernoulli bending model. Thick/short beams, stability, support bearing, connections, material failure and full design-code checks require additional analysis.

What limitation matters for this calculation?

Straight prismatic Euler–Bernoulli beam; linear elastic material, constant EI, small displacement and ideal supports. No shear deformation, lateral-torsional buckling, connection design, material failure, code factors or certified safe load. Entered steel E=200 GPa is an illustrative room-temperature value, not an allowable stress.

How do I use this steel beam deflection calculator?

Entered steel E=200 GPa is an illustrative room-temperature value, not an allowable stress. Calculate support reactions, shear force, bending moment, slope and elastic deflection for the stated simply supported beam.
EId4vdx4=q(x)
dMdx=V
dVdx=q(x)

Hermite beam stiffness uses consistent distributed loads. Exact element load integration recovers the response; q(x) is positive upward.

What do the starting values represent?

They are editable numerical examples. Measure actual dimensions and use material properties, support details and loads appropriate to the real member. They are not prescribed design values or a stock-size recommendation.

Does this result establish a safe beam size?

No. The stated calculation does not establish building-code compliance, allowable strength, connection capacity, stability, fire resistance or suitability for construction. A complete structural design needs all relevant checks and a qualified project-specific assessment.

Which unit system does the calculator use?

Dimension switching converts the labelled length inputs. Forces, line loads, elastic modulus and other properties retain the units printed beside them. Results include common metric and imperial equivalents where meaningful.

Can I export the calculation to Excel?

After calculation, Export CSV saves numerical results and submitted inputs. This is a text table, not a native Excel formula workbook, proprietary analysis file or signed engineering report.

Where do the formulas come from?

Published references appear below with full plain-text addresses. Formulas, assumptions, worked examples and comparison tables are stored directly in the pages; no external property lookup is required.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.

  • American Wood Council Design Aid 6: Beam Design Formulas, simple uniform and central point-load caseshttps://awc.org/wp-content/uploads/2021/12/AWC-DA6-BeamFormulas-0710.pdf
  • Delft University of Technology, L. Bosscher thesis, Appendix A.1 equations A.1–A.9: Euler–Bernoulli beam stiffnesshttps://repository.tudelft.nl/file/File_5cfe79e8-3268-45fd-a0a2-ec9130ea63b7
  • Penn State Mechanics Map: area moments of inertia by composite parts and parallel-axis theoremhttps://mechanicsmap.psu.edu/websites/A2_moment_intergrals/A2-9_area_moments_composite/areamomentcomposite.html
  • NIST Guide to the SI: conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors
  • SSAB: 20 Questions about Steel, Questions 3 and 10; approximate room-temperature density and Young modulushttps://www.ssab.com/en/support/product-material-data/steel/20-questions